Electro‐surgical equipment at radio‐frequency (radio‐surgery).

SURTRON® FLASH 160 HF , is a High Frequency RadioSurgical equipment which is suitable to precision monopolar and bipolar surgery and micro-surgery without tissue alterations.

SURTRON® FLASH 160 HF , can supply RF operative powers either for programmable time as short as hundreds of a second.

SURTRON® FLASH 160 HF through its performances allows pure CUT, cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, BIPOLAR coagulation and ABLATION. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. In the bipolar coagulation modality can be activated a detection system of the tissues impedance with automatic activation and automatic stop when it coagulation is achieved (AUTOSTART – AUTOSTOP).

SURTRON® FLASH 160 HF , allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.

CONTROLS

Patient/Plate circuit monitoring

Output power monitoring

Self check control

SAFETY

EN60601-1

EN60601-1-2

EN60601-2-2

Electrical Class: I CF

MDD 93/42/EC Class: II b

Categoría:

Descripción del producto

Electro‐surgical equipment at radio‐frequency (radio‐surgery).

SURTRON® FLASH 160 HF , is a High Frequency RadioSurgical equipment which is suitable to precision monopolar and bipolar surgery and micro-surgery without tissue alterations.

SURTRON® FLASH 160 HF , can supply RF operative powers either for programmable time as short as hundreds of a second.

SURTRON® FLASH 160 HF through its performances allows pure CUT, cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, BIPOLAR coagulation and ABLATION. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. In the bipolar coagulation modality can be activated a detection system of the tissues impedance with automatic activation and automatic stop when it coagulation is achieved (AUTOSTART – AUTOSTOP).

SURTRON® FLASH 160 HF , allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.

CONTROLS

Patient/Plate circuit monitoring

Output power monitoring

Self check control

SAFETY

EN60601-1

EN60601-1-2

EN60601-2-2

Electrical Class: I CF

MDD 93/42/EC Class: II b